BestHonestPro
Get a free shortlist
Jobs we cover
Water damageAvg $3,868MoldAvg $2,368BiohazardAvg $4,000RoofingReplacement avg $9,608Garage doorsRepair avg $265Plumbing$100 to $500 per hourHVACRepair avg $350Commercial HVACInstalled $7.5k to $35k
Before you hire anyone
Something wrong right now? Start here How we choose, and what we cannot promise About us Contact Privacy Terms

What is wrong?HVAC

Right now

Hissing or bubbling: a leak, gas or refrigerant

Trane says hissing is not a normal sound and could signal a gas leak or a refrigerant leak, and lists it among the sounds that mean turn the system off. If there is any gas smell with it, it is an evacuation, not a repair call.

If you smell rotten eggs or gas with the hiss, leave the house and call 911 or the gas utility from outside. Otherwise, switch the thermostat to OFF.

What is probably happening

  • Refrigerant escaping from a fitting, a coil, or a valve. Often a hiss or a bubbling at the indoor coil or the outdoor unit, sometimes with an oily spot.
  • On a gas furnace, a hiss at the gas valve or a fitting is gas. Smell for it.
  • A hiss only at shutdown that lasts a few seconds is often just pressures equalizing and is normal.

Do this in the next five minutes

  1. Smell test first. Any gas smell: out of the house, call the utility.
  2. No gas smell: thermostat to OFF.
  3. Note where the hiss is: indoor coil, outdoor unit, or the copper lines.
  4. Do not touch a frosted or oily spot on the lines.
  5. Book a visit and say: hissing at the (location), no gas smell, system off.

Do not

  • Do not accept a top-off. A hiss means refrigerant is leaving now. Refilling without repair just vents it again, and intentional venting is prohibited under federal law.
  • Do not run the system low on charge. It burns out the compressor.

Who to call

Gas utility if there is any gas smell. Otherwise a licensed HVAC technician with EPA Section 608 certification

Only a Section 608 certified technician may open the refrigerant circuit, find the leak, repair it and recharge. The utility, not a contractor, handles a gas leak.

BestHonestPro is a free comparison resource, not a contractor. There is nothing to sign up for and we do not sell your details. When we begin connecting callers to contractors, we will be paid a referral fee by the contractor, never by you, and this line will say so.

What it should cost

$250 to $1,500

Refrigerant leak repair, national range. If the leaking coil must be replaced, $600 to $2,400

Source: Angi, HVAC repair cost, updated August 2026. View source

National published range, not a quote for your job. The full cost table for this trade is on the hvac page.

Ask this contractor, on the phone, before anyone comes out

Tap each one as you ask it.

  • Where exactly is the leak, and how did you find it: electronic detector, dye, or nitrogen pressure test?
  • Is the leak repairable, or does the coil need replacing?
  • What refrigerant is this, what is the price per pound, and how many pounds did it take?
  • Will you write the leak location and the final pressures on the invoice?

End the call if

  • Refrigerant added with no leak location on the invoice.
  • A replacement pushed because 'this refrigerant is banned'. Servicing an existing R-410A system is not banned.
Where this comes from
Get a free shortlist